NSCLC Radiogenomics, CT to FDG-PET
CT (source) and FDG-PET in body-weight SUV (target) of one patient's PET/CT session, the CT brought onto the PET grid through their shared scanner frame (NSCLC Radiogenomics collection).
10 test caseswhole bodysource CT, target PET
Read before comparing (6)
- Case. A CT and an attenuation-corrected FDG-PET of one PET/CT session; prepare.py checks that both DICOM series share their FrameOfReferenceUID. Nothing is registered: the CT is resampled onto the PET grid with a cubic B-spline, air outside its field, and rounded to whole Hounsfield units.
- Target. Body-weight SUV from the PET's rescale values and its DICOM dose, weight and decay information (AutoPET_CTPET_Syn.suv_factor). The mask is the body in the shared field of view (AutoPET_CTPET_Syn.body).
- Motion. The PET and the CT have different acquisition durations, and the shared frame does not remove breathing motion between them. Tracer uptake is not set by CT anatomy alone.
- Range. A dynamic range of 20 SUV puts PSNR and SSIM on the scale of the other FDG-PET synthesis datasets; it clips neither the target nor its errors.
- Baseline. On the 10 test cases a constant at the target's median inside the mask scores, as the median over the cases and its range, an MAE of 0.47 (0.29 to 0.60) SUV, a PSNR of 24.0 (16.6 to 28.9) dB and an SSIM of 0.77 (0.73 to 0.85).
- Overlap. MSD_Lung's 20 cases, other images (the diagnostic thin-section CTs), are of patients R01-004 to R01-081. MSD_Lung's 42 training cases not built and the decathlon's 32 unlabelled test scans were not matched to patients and may be of this pool. AMC is a separate cohort. SAROSBodyCT excludes the NSCLC Radiogenomics collection.
No method has a result on every case of this dataset yet.
Case by case
Click a score to look at that result: the target image, and over it the method's synthetic image. Underlined scores have their image; for the others you see the case without the result.
About the data
The first test caseClick to look at every case.
- Test cases
- 10 test patients drawn with seed 2026 by cohort, R01 or AMC, then 10 development patients, one session each. The R01 pool starts at R01-082, after MSD_Lung's patients. prepare.py pins each selected patient's PET and CT series.
- Truth
- target image as released the attenuation-corrected FDG-PET of the same PET/CT session in body-weight SUV, aligned by the scanner frame
- Source
- www.cancerimagingarchive.net/collection/nsclc-radiogenomics
doi.org/10.7937/K9/TCIA.2017.7hs46erv - Licence
- CC BY 3.0
10 cases for tuning, never tested
R01-128, AMC-040, R01-126, R01-100, AMC-004, R01-140, R01-117, AMC-032, R01-163, R01-087