Lung-PET-CT-Dx, CT to FDG-PET
CT (source) and FDG-PET in body-weight SUV (target) of one lung cancer patient's PET/CT session at the Second Affiliated Hospital of Harbin Medical University, the CT brought onto the PET grid through their shared scanner frame (Lung-PET-CT-Dx collection).
10 test casesthoraxsource CT, target PET
Read before comparing (9)
- Pairs. One Siemens Biograph 64 mCT session a patient: the attenuation-corrected PET and the whole-body attenuation-correction CT ('CT WB 1.0 B30f', or '3.0' on five of the pool; no contrast agent in its header), in one frame of reference. prepare.py checks the shared FrameOfReferenceUID and pins both series. Nothing is registered: the CT is resampled onto the PET grid with a cubic B-spline, air outside it, and rounded to whole Hounsfield units.
- Field. The collection keeps only part of most CTs, the chest: 160 to 290 mm of the PET's 720 to 980 on 17 of the 20 cases, where Lung_Dx-A0164 keeps all 849 mm, Lung_Dx-A0220 675 and Lung_Dx-G0037 399. Where the PET runs past the CT the source reads -1024 and the body is left out of the mask.
- Target. Body-weight SUV from the PET's rescale values and its DICOM dose, weight and decay information (AutoPET_CTPET_Syn.suv_factor), 49 to 127 minutes after injection in the pool. The mask is the body in the shared field, lungs included (AutoPET_CTPET_Syn.body).
- Motion. Patients breathed freely during both scans, and the PET lasts minutes where the CT lasts seconds: the lung bases and the heart disagree by an amount nobody measured.
- Uptake. Every patient has a biopsied lung cancer (adenocarcinoma, small-cell or squamous, the letter in the patient's name); what the CT does not show counts against every method.
- Range. A dynamic range of 20 SUV puts PSNR and SSIM on the scale of the other FDG-PET synthesis datasets.
- Baseline. On the 10 test cases a constant at the target's median inside the mask scores, as the mean over the cases and its range, an MAE of 0.37 (0.31 to 0.44) SUV, a PSNR of 29.0 (25.2 to 33.0) dB and an SSIM of 0.78 (0.73 to 0.81).
- Unused. The 85 other PET studies have no whole-body CT: 55 only a chest CT ('Thorax' B31f or B70f), 27 only the fused 'Range' reformats, 3 neither. The radiologists' tumour boxes and BAMF's automatic lung masks are not used.
- Overlap. SAROS labels CTs of 17 Lung-PET-CT-Dx patients. SAROSBodyCT holds six of them: Lung_Dx-A0165 is held out here, the five others have no whole-body CT. SAROS also labels the CT of the test case Lung_Dx-A0220 (its case_737, a training fold), which SAROSBodyCT does not hold. No other descriptor names the collection.
No method has a result on every case of this dataset yet.
Case by case
Click a score to look at that result: the target image, and over it the method's synthetic image. Underlined scores have their image; for the others you see the case without the result.
About the data
- Test cases
- 10 test patients drawn with seed 2026, then 10 development patients, one session each. The pool is the 48 patients whose PET/CT study holds a whole-body CT and an attenuation-corrected PET; Lung_Dx-A0165, whose CT SAROSBodyCT shows, is held out.
- Truth
- target image as released the attenuation-corrected FDG-PET of the same PET/CT session in body-weight SUV, aligned by the scanner frame
- Source
- www.cancerimagingarchive.net/collection/lung-pet-ct-dx
doi.org/10.7937/TCIA.2020.NNC2-0461
services.cancerimagingarchive.net/nbia-api/services/v1/getSeries?Collection=Lung-PET-CT-Dx - Licence
- CC BY 4.0
10 cases for tuning, never tested
Lung_Dx-B0034, Lung_Dx-G0041, Lung_Dx-G0035, Lung_Dx-G0053, Lung_Dx-A0178, Lung_Dx-G0033, Lung_Dx-A0202, Lung_Dx-G0050, Lung_Dx-A0222, Lung_Dx-A0251