fidopt Interactive view

ACRIN 6668, CT to FDG-PET

CT and FDG-PET from one PET/CT session of a patient with non-small-cell lung cancer in the ACRIN 6668 trial: the CT is the source, the PET in body-weight SUV on its native grid the target.

11 test caseswhole bodysource CT, target PET
Read before comparing (6)
  • Pairs. A case is a CT and an attenuation-corrected FDG-PET from one PET/CT session, one session a patient. prepare.py checks that both series share their FrameOfReferenceUID and pins their SeriesInstanceUIDs. Nothing is registered: the CT is resampled onto the PET grid with a cubic B-spline, air outside the CT, and rounded to whole Hounsfield units.
  • Target. Body-weight SUV, computed from the PET's rescale values and its DICOM dose, weight and decay information by AutoPET_CTPET_Syn.suv_factor. The mask is the body in the shared field of view, made by AutoPET_CTPET_Syn.body.
  • Limits. The PET and CT have different acquisition durations, and scanner alignment does not remove the respiratory motion between them. Tracer uptake is not determined by CT anatomy alone.
  • Range. A dynamic range of 20 SUV gives PSNR and SSIM the same scale as the corpus's other FDG-PET synthesis datasets; it clips neither the target nor its errors.
  • Baseline. On the 11 test cases a constant at the target's median inside the mask scores, as the median over the cases and its range, an MAE of 0.53 (0.33 to 0.65) SUV, a PSNR of 23.8 (13.7 to 28.3) dB and an SSIM of 0.74 (0.70 to 0.81).
  • Overlap. The ACRIN-NSCLC-FDG-PET patients of every descriptor were checked. SAROSBodyCT holds 23: the 11 in this pool are held out here, the 12 others are not eligible. TotalSegMR's test image s0031 may be an MR series of this collection from a patient its notes do not name: an MR, neither this dataset's CT nor its PET.

No method has a result on every case of this dataset yet.

Case by case

Click a score to look at that result: the target image, and over it the method's synthetic image. Underlined scores have their image; for the others you see the case without the result.

About the data

The first test case of ACRIN 6668, CT to FDG-PET
The first test caseClick to look at every case.
Test cases
11 test patients drawn with seed 2026, stratified by scanner model, and ten development patients, all distinct. The pool is the 129 patients with an eligible paired session; the 11 of them among SAROSBodyCT's test and development cases, whose CT SAROSBodyCT shows, are held out, leaving 118.
Truth
target image as released the attenuation-corrected FDG-PET of the same PET/CT session in body-weight SUV, aligned by the scanner frame
Licence
CC BY 3.0
10 cases for tuning, never tested

ACRIN-NSCLC-FDG-PET-039, ACRIN-NSCLC-FDG-PET-087, ACRIN-NSCLC-FDG-PET-129, ACRIN-NSCLC-FDG-PET-091, ACRIN-NSCLC-FDG-PET-232, ACRIN-NSCLC-FDG-PET-033, ACRIN-NSCLC-FDG-PET-096, ACRIN-NSCLC-FDG-PET-192, ACRIN-NSCLC-FDG-PET-143, ACRIN-NSCLC-FDG-PET-128