STRAUS 3D synthetic echocardiography

B-mode frames 0 and 10 of one simulated 3D echocardiographic sequence, one cardiac activation scenario, with the simulation's myocardial mesh vertices paired between the two frames (STRAUS).

8 test pairsheartsame simulationfixed US, moving USdelivered alignedresearch only
Read before comparing (5)
  • Images. The released Cartesian B-mode MetaImage data, not the RF polar data, with their spacing, origin, direction and int16 values. The source's MATLAB code main_map_gt2polar.m treats mesh coordinates as Cartesian millimetres on the B-mode grid, so no polar conversion is applied.
  • Coordinates. The source's MATLAB view spans each axis from zero to Dimension×Spacing, while a MetaImage header puts the last voxel centre at (Dimension−1)×Spacing. The published header is used throughout; no sub-voxel precision beyond that convention is claimed.
  • Truth. The simulated mesh motion, not annotated human heart motion. Frame 10 is a fixed index, not a claim that every scenario reaches end systole there.
  • Ranked apart. Eight correlated simulated scenarios, a synthetic truth and nonstandard citation-ware terms.
  • Licence. Preparing the data locally gives no permission to republish it.

No method has a result on every pair of this dataset yet.

Pair by pair

Click a score to look at that result: the fixed image, and over it the moving image after registration, with the annotations. Underlined scores have their image; for the others you see the pair without the result. A green cell gained against no registration on that pair, a red one lost.

About the data

Test pairs
All eight released scenarios are test cases, and no development case is made from other frames of the same simulations. The scenarios share one simulation framework and may share geometry: they are not eight independent patients.
Truth
landmarks a known deformation The same indexed vertices of the provider electromechanical myocardial meshes at frames 0 and 10. Topology and vertex count must agree. Vertices outside either image header grid or without a nonzero B-mode value in a 3×3×3 neighborhood in either frame are excluded before scoring; every surviving node is retained.
Licence
Citation-ware: the provider permits use with citation to Alessandrini et al., A pipeline for the generation of realistic 3D synthetic echocardiographic sequences: methodology and open-access database, IEEE TMI 34(7), 2015. No standard data redistribution/commercial licence is stated.