fidopt Interactive view

Chest and body CT, inter-patient

2 datasets, 29 test pairs. A method is ranked here when it has a result on every pair of every one of them.

Read before comparing

  • 1 dataset of this kind is shown below and not ranked on the official board: its licence does not allow a public leaderboard. The research board (Research, above the ranking) ranks it too.

Ranking OfficialResearch

Provisional: no method has run on every dataset here yet. The methods that cover the most datasets come first, then the lower mean place on those.
#MethodMean rankDatasetsLCTSCPediatric-CT-SEG
1ConvexAdam (MIND)GPUapp1.331 of 2114/17
2DemonsCPUapp1.671 of 22
1 place in that table, 1 is best2/10 cases done, not ranked yetn/a does not apply not run some cases failed

Under each dataset, the method's place in that dataset's table: 1 is best, the darker the better. The mean rank averages its places over the datasets.

The scores, dataset by dataset

Each score is followed by its change against no registration: green when the method did better, red when it did worse.

RibSeg v2

30 pairs · ordered on Dice and SDlogJ research only
#MethodDiceChangeSDlogJ
1Demons0.142+0.0990.088
2NiftyReg0.312+0.2690.774
No registration0.0430.000
1 dataset without a ranked method yet

Pediatric-CT-SEG.