deeds
deedsBCV with its defaults (MIND-SSC, discrete optimisation), from the corpus's rigidly aligned pair, on an isotropic grid as its README asks for thick slices.
RegistrationCPUversion 00b4653every datasetMIT
Run it
With its KonfAI app, at the benchmark's settings (the fidopt app repositories are private for now: a Hugging Face token with access opens them):
pip install konfai-apps konfai-apps infer fideus-labs/fidopt-registration:Deeds -i fixed.nii.gz -i moving.nii.gz -o out
The app on Hugging Face: its model, its settings and how it is scored.
Where it works
Its place on each kind of problem it has results on, among the methods ranked there. A method that leads one problem can trail another: read the one closest to yours.
| Problem | Place | Ranked | Datasets |
|---|---|---|---|
| Repeat scans, same patient | 1 | of 5 | 1 of 1 |
| Simulated thoracic CBCT, known motion | 2 | of 4 | 1 of 1 |
| Repeat chest CT, same patient, tumour truth | 5 | of 5 | 1 of 1 |
| Two modalities, same patient | not ranked yet | 2 of 5 | |
| Same patient, truth made by a program | not ranked yet | 2 of 8 |
Results
| Dataset | # | Read by | Score | Change | SDlogJ | Failed | Time s |
|---|---|---|---|---|---|---|---|
| PROMISE12 | 1 | Dice | 0.814 | +0.198 | 0.086 | 0 | 18 |
| PSMA-PET-CT-Lesions follow-up (Learn2Reg 2026 PSMAReg) | 1 | TRE mm | 5.13 | −2.45 | 0.088 | 0 | 262 |
| Pelvic-Reference-Data | 4 | TRE mm | 2.40 | −0.32 | 0.186 | 0 | 74 |
| Pelvic landmarks CT/CT (LUMC) | 1 | Dice | 0.758 | +0.143 | 0.090 | 0 | 129 |
| Pelvic landmarks MR/CT (LUMC) | 1 | Dice | 0.681 | +0.152 | 0.081 | 0 | 24 |
| Cardiac CT of growing pigs (A heart for pigs) | Dice | 0.714 | = | 0.000 | 10 | ||
| Prostate-MRI-US-Biopsy | 2 | Dice | 0.514 | −0.105 | 0.155 | 0 | 15 |
| LCTSC CT and simulated CBCT, known deformation | 2 | TRE mm | 0.29 | −0.95 | 0.018 | 0 | 21 |
| QIN-PROSTATE-Repeatability | 1 | Dice | 0.772 | +0.128 | 0.066 | 0 | 25 |
| QUADRA_HC, whole-body CT test-retest | 2 | Dice | 0.843 | +0.291 | 0.085 | 0 | 195 |
| RIDER Lung CT | 5 | Dice | 0.780 | +0.044 | 0.070 | 0 | 260 |
- Reference
- Heinrich et al., IEEE Transactions on Medical Imaging 2013