Colorectal-Liver-Metastases, liver and veins
Portal venous CT of one patient with colorectal liver metastases, with the liver, the hepatic veins and the portal veins segmented (Colorectal-Liver-Metastases).
Read before comparing (1)
- Cases. The cases are the fixed images of CRLMCT's pairs, each on its pair's side of the split. The moving images are left out: their headers carry the pair's start, so they are not the images as delivered.
| Accuracy | Cost | |||||||
|---|---|---|---|---|---|---|---|---|
| # | Method | Dice | Surface Dice | HD95 mm | Time s | RAM GB | GPU GB | Images |
| 11–5 | MONAI wholeBody CTGPUapp1 of 3 structures | 0.949 ±0.004 | 0.645 ±0.047 | 19.35 ±2.04 | 16 | 3.8 | 7.1 | |
| 21–5 | KonfAI segmentation app · TotalSegmentator (total), KonfAI appGPUapp1 of 3 structures | 0.948 ±0.005 | 0.636 ±0.052 | 18.98 ±1.87 | 20 | 3.5 | 5.6 | |
| 31–5 | KonfAI segmentation app · TotalSegmentator (total), the authors' packageGPUapp1 of 3 structures | 0.948 ±0.005 | 0.636 ±0.055 | 19.05 ±1.74 | 19.8 | 3.6 | ||
| 41–5 | KonfAI segmentation app · MRSegmentator, KonfAI appGPUapp1 of 3 structures2 failed | 0.759 ±0.286 | 0.519 ±0.204 | 19.57 ±2.48 | 22 | 3.7 | 6.4 | |
| 51–5 | CT-FM whole-body segmentationGPUapp1 of 3 structures | 0.861 ±0.089 | 0.453 ±0.093 | 31.13 ±11.80 | 24 | 7.2 | 6.9 | |
The order averages each method's ranks on Dice, Surface Dice, HD95 mm, so the first one is not always the best in every column. ± is the 95% interval of the mean over the 10 cases. Two neighbours are tied when a paired Wilcoxon test on the shared cases does not find the upper one better on Dice (5%): the places a method could hold are then shown under its own. The best value of each column is in colour. Click a row to see its images, a column title to sort by it. Time and memory measured on Workstation.
1 result not ranked: an older run, cases still missing, or a failure on every case
| Accuracy | Cost | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| # | Method | Dice | Surface Dice | HD95 mm | Time s | RAM GB | GPU GB | Machine | Images |
| MONAI wholeBody CTGPUapp1 of 3 structuresolder run | 0.949 ±0.004 | 0.645 ±0.047 | 19.35 ±2.04 | 11 | 2.4 | 6.9 | Laptop | ||
Dice: how much the organ contours overlap, 1 is perfect. Surface Dice: the share of the contours' surfaces within a tolerance of each other, 1 is perfect. HD95: distance between the contours' surfaces.
Case by case
Click a score to look at that result: the image, the truth in green and the method's map in red. Underlined scores have their image; for the others you see the case without the result.
About the data
- Truth
- contours by experts 3 structures, the dataset's segmentations: 1 the liver, its tumours included, then 2 the hepatic veins and 3 the portal veins over it; made semi-automatically in Scout Liver by an expert radiologist or fellow
- Source
- www.cancerimagingarchive.net/collection/colorectal-liver-metastases
doi.org/10.7937/QXK2-QG03
doi.org/10.1038/s41597-024-02981-2 - Licence
- CC BY 4.0
10 cases for tuning, never tested
1037_1030/fixed, 1063_1164/fixed, 1054_1176/fixed, 1167_1004/fixed, 1137_1062/fixed, 1003_1091/fixed, 1028_1100/fixed, 1180_1020/fixed, 1134_1013/fixed, 1192_1105/fixed