MIDRC-RICORD-1A
One chest CT of an adult with COVID-19, from four sites in four countries, with the infectious opacities outlined slice by slice by a thoracic radiologist (MIDRC-RICORD-1A, RSNA and the Society of Thoracic Radiology).
10 test caseslungimage CTresearch only
Read before comparing (8)
- Pool. 120 chest CT studies of 110 COVID-19 positive adults from four sites, named by pseudonymous site ids (419639, 440808, 660042, SITE2); 118 studies are outlined. A patient is one case: the earliest outlined study of the eight patients with several. Left out: two patients without outlines and four whose outlines hold only non-infectious findings.
- Truth. Six subspecialist thoracic radiologists outlined the findings slice by slice under a schema agreed with the STR and EuSoMII (Tsai et al. 2021), only opacities and nodules over 1 cm, so a smaller opacity is background; 86 of the pool's 104 series hold one reader's polygons, 18 two readers'. No agreement between readers is published. Graded expert. Some outlines skip a slice now and then: on 419639-001155 (slices 1.25 mm apart) the coronal view shows upper-lobe opacities missing on single slices.
- Labels. lung_covid_infiltrate merges the three infectious findings, as COVIDLungCT's infection. The non-infectious findings (atelectasis, nodule or mass, other opacity) are taken out of the truth and of the prediction (ignore.nii.gz), where no infectious finding lies: present on 3 test CTs, 1.9 mL at most. The surface Dice uses 3 mm, as COVIDLungCT.
- Cases. The test infiltrates hold 0.9 to 2312 mL (median 451 mL); 660042-000100 (0.9 mL in 5 polygons) and SITE2-000198 (1.7 mL of tree-in-bud and a cavity) are small, where a single missed or extra blob moves the Dice from 0 to 1.
- Images. The outlined series as delivered, in Hounsfield units, slices 1.25 to 3 mm apart, pixels 0.61 to 0.88 mm on the test CTs; three read -3024 outside the reconstructed circle. prepare.py stops on a series whose slices are not evenly spaced.
- Start. A mask of the whole image scores a Dice of 0.022 at the median of the test CTs (0 to 0.103), an Otsu mask 0.032. TotalSegmentator 2.18.0's five lung lobes as a mask score 0.705 on 440808-000008, whose opacities fill 66% of the lungs, and 0.359 on SITE2-000001 (25%).
- Overlap. No other dataset of the corpus names MIDRC or RICORD; COVIDLungCT's CTs come from Coronacases and Radiopaedia. RICORD 1b (COVID-negative CTs) and 1c (radiographs) are not used.
- Outside numbers. None: RICORD has no challenge and no official split.
No method has a result on every case of this dataset yet.
Case by case
Click a score to look at that result: the image, the truth in green and the method's map in red. Underlined scores have their image; for the others you see the case without the result.
About the data
- Test cases
- 10 test CTs drawn with seed 2026 among the 93 patients outside development, the four sites in proportion, and 10 development CTs. A case is a patient's earliest outlined study; the 104 patients whose outlines hold an infectious finding make the pool, less SITE2-000051, whose series holds two different images at ten slice positions. RICORD publishes no test set.
- Truth
- contours by experts the polygons of the findings 'Infectious opacity', 'Infectious TIB/micronodules' and 'Infectious cavity' on the outlined axial series, filled with their edge: drawn by hand on each slice in MD.ai by one of six thoracic radiologists (6 years of experience on average), one reader a series for most; the non-infectious findings outlined beside them (nodule or mass, atelectasis, other opacity) are the ignore region
- Source
- www.cancerimagingarchive.net/collection/midrc-ricord-1a
doi.org/10.7937/VTW4-X588
doi.org/10.1148/radiol.2021203957
pmc.ncbi.nlm.nih.gov/articles/PMC7993245
docs.md.ai/data/json
github.com/QIICR/dcmqi/blob/add-mdai-converter/util/mdai2dcm.py - Licence
- CC BY-NC 4.0
10 cases for tuning, never tested
SITE2-000024, 440808-000019, 660042-000063, SITE2-000016, 419639-001336, SITE2-000007, SITE2-000038, 440808-000016, 660042-000107, SITE2-000174