fidopt Interactive view

LCTSC, thoracic organs at risk

Radiotherapy planning CT of one patient's thorax, with five organs at risk contoured by hand (AAPM Lung CT Segmentation Challenge 2017).

24 test caseslungimage CT
Read before comparing (2)
  • Cases. Both CTs and their contours of each LCTSC test pair, shared with that dataset rather than stored twice. A moving CT and its labels keep the intensity-derived start written in their headers.
  • Check. On test CT Test-S1-101, TotalSegmentator matches the expert contours at a Dice of 0.757 for the heart, 0.751 for the oesophagus, 0.977 for each lung and 0.842 for the spinal cord: a sanity check on one case, not a baseline.
AccuracyCost
#MethodDiceSurface DiceHD95 mmTime sRAM GBGPU GBMachineImages
1lungmaskGPUapp2 of 5 structures0.944 ±0.0220.800 ±0.0597.48 ±3.24143.54.4Workstation
2lungmask · lobesGPUapp2 of 5 structures0.931 ±0.0440.793 ±0.0666.82 ±3.03633.84.5Workstation
33–4MONAI wholeBody CTGPUapp3 of 5 structures0.858 ±0.0230.713 ±0.05713.33 ±7.75163.116.8Laptop
43–4KonfAI segmentation app · MRSegmentator, KonfAI appGPUapp4 of 5 structures0.857 ±0.0130.640 ±0.04212.45 ±1.4611.68.3Workstation
55–6KonfAI segmentation app · TotalSegmentator (total), the authors' packageGPUapp0.835 ±0.0160.657 ±0.04419.81 ±4.1319.16.3Workstation
65–6KonfAI segmentation app · TotalSegmentator (total), KonfAI appGPUapp0.835 ±0.0150.654 ±0.04333.16 ±10.55408.25.7Workstation
7KonfAI segmentation app · IMPACTSeg body, KonfAI appGPUapp1 of 5 structures0.731 ±0.0430.660 ±0.05249.05 ±17.821.73.5Workstation

The order averages each method's ranks on Dice, Surface Dice, HD95 mm, so the first one is not always the best in every column. ± is the 95% interval of the mean over the 24 cases. Two neighbours are tied when a paired Wilcoxon test on the shared cases does not find the upper one better on Dice (5%): the places a method could hold are then shown under its own. The best value of each column is in colour. Click a row to see its images, a column title to sort by it.

4 results not ranked: an older run, cases still missing, or a failure on every case
AccuracyCost
#MethodDiceSurface DiceHD95 mmTime sRAM GBGPU GBMachineImages
KonfAI segmentation app · TotalSegmentator (total), KonfAI appGPUappolder run0.835 ±0.0150.654 ±0.04333.16 ±10.55303.812.5Laptop
lungmaskGPUapp2 of 5 structuresolder run0.944 ±0.0220.800 ±0.0597.48 ±3.24543.6Laptop
lungmask · lobesGPUapp2 of 5 structuresolder run0.931 ±0.0440.793 ±0.0666.82 ±3.03852.15.0Laptop
MONAI wholeBody CTGPUapp3 of 5 structuresfailed on every case0.000 ±0.0000.000 ±0.000Workstation

Dice: how much the organ contours overlap, 1 is perfect. Surface Dice: the share of the contours' surfaces within a tolerance of each other, 1 is perfect. HD95: distance between the contours' surfaces.

Case by case

Click a score to look at that result: the image, the truth in green and the method's map in red. Underlined scores have their image; for the others you see the case without the result.

About the data

The first test case of LCTSC, thoracic organs at risk
The first test caseClick to look at every case.
Test cases
All 24 released Test patients, each once, from LCTSC's test pairs. Ten development Train patients, 4/3/3 across S1/S2/S3, chosen from LCTSC's development patients in the PsCBCT family's SHA256 order; the other ten stay family training exclusions but are not cases here.
Truth
contours by experts the dataset's manual contours of five organs at risk: 1 heart, 2 oesophagus, 3 left lung, 4 right lung, 5 spinal cord
Licence
CC BY 3.0
10 cases for tuning, never tested

Train-S1-007_Train-S1-006/moving, Train-S1-008_Train-S1-003/fixed, Train-S1-008_Train-S1-003/moving, Train-S1-010_Train-S1-009/moving, Train-S2-001_Train-S2-012/fixed, Train-S2-002_Train-S2-010/moving, Train-S2-004_Train-S2-011/moving, Train-S3-006_Train-S3-004/fixed, Train-S3-006_Train-S3-004/moving, Train-S3-011_Train-S3-009/moving