fidopt Interactive view

Pediatric-CT-SEG, organs of children

Chest, abdomen and pelvis CT of one child with up to 28 structures contoured (Pediatric-CT-SEG).

17 test casesthorax, abdomenimage CT
Read before comparing (1)
  • Cases. The fixed images of PediatricCT's pairs, each on its pair's side of the split. The moving images are left out.
AccuracyCost
#MethodDiceSurface DiceHD95 mmTime sRAM GBGPU GBImages
1lungmaskGPUapp2 of 28 structures0.922 ±0.0340.785 ±0.06712.18 ±4.12204.54.7
2KonfAI segmentation app · TotalSegmentator (total), the authors' packageGPUapp21 of 28 structures0.633 ±0.0700.495 ±0.06011.71 ±2.5819.93.8
2lungmask · lobesGPUapp2 of 28 structures0.896 ±0.0700.765 ±0.08912.22 ±4.101185.14.9
44–6KonfAI segmentation app · TotalSegmentator (total), KonfAI appGPUapp21 of 28 structures0.624 ±0.0710.481 ±0.06116.35 ±5.94172.84.9
54–6KonfAI segmentation app · IMPACTSeg body, KonfAI appGPUapp1 of 28 structures2 failed0.547 ±0.1220.395 ±0.08928.97 ±10.25152.06.2
64–6KonfAI segmentation app · MRSegmentator, KonfAI appGPUapp20 of 28 structures8 failed0.315 ±0.1710.242 ±0.13339.17 ±25.62315.19.1
64–6MONAI wholeBody CTGPUapp19 of 28 structures7 failed0.304 ±0.1380.211 ±0.09917.34 ±3.22184.26.2

The order averages each method's ranks on Dice, Surface Dice, HD95 mm, so the first one is not always the best in every column. ± is the 95% interval of the mean over the 17 cases. Two neighbours are tied when a paired Wilcoxon test on the shared cases does not find the upper one better on Dice (5%): the places a method could hold are then shown under its own. The best value of each column is in colour. Click a row to see its images, a column title to sort by it. Time and memory measured on Workstation.

4 results not ranked: an older run, cases still missing, or a failure on every case
AccuracyCost
#MethodDiceSurface DiceHD95 mmTime sRAM GBGPU GBMachineImages
KonfAI segmentation app · TotalSegmentator (total), KonfAI appGPUapp21 of 28 structuresolder run0.624 ±0.0710.481 ±0.06116.35 ±5.9492.68.5Laptop
lungmaskGPUapp2 of 28 structuresolder run0.922 ±0.0340.785 ±0.06712.18 ±4.12482.82.9Laptop
lungmask · lobesGPUapp2 of 28 structuresolder run0.896 ±0.0700.765 ±0.08912.22 ±4.101712.85.0Laptop
MONAI wholeBody CTGPUapp19 of 28 structuresolder run0.528 ±0.0660.373 ±0.05721.68 ±4.70142.89.6Laptop

Dice: how much the organ contours overlap, 1 is perfect. Surface Dice: the share of the contours' surfaces within a tolerance of each other, 1 is perfect. HD95: distance between the contours' surfaces.

Case by case

Click a score to look at that result: the image, the truth in green and the method's map in red. Underlined scores have their image; for the others you see the case without the result.

About the data

The first test case of Pediatric-CT-SEG, organs of children
The first test caseClick to look at every case.
Truth
contours by experts up to 28 structures a child, the dataset's contours: 25 organs drawn by hand, the lungs and the bones from a threshold corrected by hand
Licence
CC BY 4.0
16 cases for tuning, never tested

34ECBB32_8877A5A3/fixed, 379_385/fixed, AA032583_6A2228AD/fixed, 7C7F4414_51733317/fixed, 4EF8F066_8975C78C/fixed, 14403912_CF79E74B/fixed, B722C905_B9DA30EF/fixed, E69AC901_B0308EC6/fixed, 642CA0DF_691FB79F/fixed, 381_8538895B/fixed, B42CD321_F369B022/fixed, 3A4DE292_4934405E/fixed, 627003CD_5AEBE68F/fixed, 47CA11F8_491B83F3/fixed, 211F45E2_29ECC095/fixed, C7D4AEFA_792705D7/fixed