PLC-CECT, delayed-phase liver segmentation
The delayed contrast phase of a primary liver cancer CT examination, with the liver label refined by clinicians: the fixed images of LiverPhasesCT, referenced on their native grid without copying or resampling.
Read before comparing (3)
- Split. LiverPhasesCT's partition is kept: 27 test patients and 24 distinct development patients. Only the delayed fixed image is used.
- Images. The provider's images lost their physical voxel size and hold an 8-bit soft-tissue window, not Hounsfield units. As LiverPhasesCT, the dataset is ranked apart, and its surface distances are not millimetres.
- Labels. Only the liver is scored; the parent's separate lesion label set does not stand in for it.
| Accuracy | Cost | |||||||
|---|---|---|---|---|---|---|---|---|
| # | Method | Dice | Surface Dice | HD95 mm | Time s | RAM GB | GPU GB | Images |
| 11–2 | KonfAI segmentation app · TotalSegmentator (total), KonfAI appGPUapp | 0.716 ±0.089 | 0.421 ±0.064 | 47.35 ±10.37 | 26 | 3.6 | 6.3 | |
| 21–2 | KonfAI segmentation app · TotalSegmentator (total), the authors' packageGPUapp | 0.668 ±0.104 | 0.407 ±0.076 | 58.30 ±11.77 | 16.3 | 3.9 | ||
| 33–4 | KonfAI segmentation app · MRSegmentator, KonfAI appGPUapp11 failed | 0.406 ±0.147 | 0.149 ±0.066 | 58.32 ±17.68 | 44 | 19.8 | 6.6 | |
| 43–4 | CT-FM whole-body segmentationGPUapp2 failed | 0.320 ±0.083 | 0.208 ±0.043 | 69.82 ±15.15 | 57 | 13.4 | 7.1 | |
| 5 | MONAI wholeBody CTGPUapp7 failed | 0.061 ±0.043 | 0.019 ±0.014 | 157.10 ±29.26 | 17 | 4.1 | 8.1 | |
The order averages each method's ranks on Dice, Surface Dice, HD95 mm, so the first one is not always the best in every column. ± is the 95% interval of the mean over the 27 cases. Two neighbours are tied when a paired Wilcoxon test on the shared cases does not find the upper one better on Dice (5%): the places a method could hold are then shown under its own. The best value of each column is in colour. Click a row to see its images, a column title to sort by it. Time and memory measured on Workstation.
2 results not ranked: an older run, cases still missing, or a failure on every case
| Accuracy | Cost | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| # | Method | Dice | Surface Dice | HD95 mm | Time s | RAM GB | GPU GB | Machine | Images |
| KonfAI segmentation app · TotalSegmentator (total), KonfAI appGPUappolder run | 0.716 ±0.089 | 0.421 ±0.064 | 47.35 ±10.37 | 16 | 3.1 | 10.6 | Laptop | ||
| MONAI wholeBody CTGPUappolder run | 0.134 ±0.057 | 0.042 ±0.018 | 138.85 ±24.30 | 11 | 2.7 | 9.3 | Laptop | ||
Dice: how much the organ contours overlap, 1 is perfect. Surface Dice: the share of the contours' surfaces within a tolerance of each other, 1 is perfect. HD95: distance between the contours' surfaces.
Case by case
Click a score to look at that result: the image, the truth in green and the method's map in red. Underlined scores have their image; for the others you see the case without the result.
About the data
- Truth
- contours by experts the liver (label 1) on each phase: the LiverMask network's segmentation refined by clinicians in ITK-SNAP
- Source
- doi.org/10.57760/sciencedb.12207
doi.org/10.1038/s41597-025-05125-2
github.com/ljwa2323/PLC_CECT - Licence
- CC BY 4.0
24 cases for tuning, never tested
P0001/fixed, P0095/fixed, P0194/fixed, P0165/fixed, P0162/fixed, P0115/fixed, P0171/fixed, P0024/fixed, P0113/fixed, P0119/fixed, P0155/fixed, P0033/fixed, P0111/fixed, P0075/fixed, P0062/fixed, P0088/fixed, P0035/fixed, P0266/fixed, P0041/fixed, P0217/fixed, P0272/fixed, P0228/fixed, P0203/fixed, P0246/fixed