fidopt Interactive view

PLC-CECT, delayed-phase liver segmentation

The delayed contrast phase of a primary liver cancer CT examination, with the liver label refined by clinicians: the fixed images of LiverPhasesCT, referenced on their native grid without copying or resampling.

27 test casesabdomenimage CT
Read before comparing (3)
  • Split. LiverPhasesCT's partition is kept: 27 test patients and 24 distinct development patients. Only the delayed fixed image is used.
  • Images. The provider's images lost their physical voxel size and hold an 8-bit soft-tissue window, not Hounsfield units. As LiverPhasesCT, the dataset is ranked apart, and its surface distances are not millimetres.
  • Labels. Only the liver is scored; the parent's separate lesion label set does not stand in for it.
AccuracyCost
#MethodDiceSurface DiceHD95 mmTime sRAM GBGPU GBImages
11–2KonfAI segmentation app · TotalSegmentator (total), KonfAI appGPUapp0.716 ±0.0890.421 ±0.06447.35 ±10.37263.66.3
21–2KonfAI segmentation app · TotalSegmentator (total), the authors' packageGPUapp0.668 ±0.1040.407 ±0.07658.30 ±11.7716.33.9
33–4KonfAI segmentation app · MRSegmentator, KonfAI appGPUapp11 failed0.406 ±0.1470.149 ±0.06658.32 ±17.684419.86.6
43–4CT-FM whole-body segmentationGPUapp2 failed0.320 ±0.0830.208 ±0.04369.82 ±15.155713.47.1
5MONAI wholeBody CTGPUapp7 failed0.061 ±0.0430.019 ±0.014157.10 ±29.26174.18.1

The order averages each method's ranks on Dice, Surface Dice, HD95 mm, so the first one is not always the best in every column. ± is the 95% interval of the mean over the 27 cases. Two neighbours are tied when a paired Wilcoxon test on the shared cases does not find the upper one better on Dice (5%): the places a method could hold are then shown under its own. The best value of each column is in colour. Click a row to see its images, a column title to sort by it. Time and memory measured on Workstation.

2 results not ranked: an older run, cases still missing, or a failure on every case
AccuracyCost
#MethodDiceSurface DiceHD95 mmTime sRAM GBGPU GBMachineImages
KonfAI segmentation app · TotalSegmentator (total), KonfAI appGPUappolder run0.716 ±0.0890.421 ±0.06447.35 ±10.37163.110.6Laptop
MONAI wholeBody CTGPUappolder run0.134 ±0.0570.042 ±0.018138.85 ±24.30112.79.3Laptop

Dice: how much the organ contours overlap, 1 is perfect. Surface Dice: the share of the contours' surfaces within a tolerance of each other, 1 is perfect. HD95: distance between the contours' surfaces.

Case by case

Click a score to look at that result: the image, the truth in green and the method's map in red. Underlined scores have their image; for the others you see the case without the result.

About the data

The first test case of PLC-CECT, delayed-phase liver segmentation
The first test caseClick to look at every case.
Truth
contours by experts the liver (label 1) on each phase: the LiverMask network's segmentation refined by clinicians in ITK-SNAP
Licence
CC BY 4.0
24 cases for tuning, never tested

P0001/fixed, P0095/fixed, P0194/fixed, P0165/fixed, P0162/fixed, P0115/fixed, P0171/fixed, P0024/fixed, P0113/fixed, P0119/fixed, P0155/fixed, P0033/fixed, P0111/fixed, P0075/fixed, P0062/fixed, P0088/fixed, P0035/fixed, P0266/fixed, P0041/fixed, P0217/fixed, P0272/fixed, P0228/fixed, P0203/fixed, P0246/fixed